Hager 46mm Deep Moulded Back Box for Shaver Sockets - Sollysta Range

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

The cable is then normally capped (covered with a protective UPVC capping) or run through some UPVC trunking/pipe to protect it and hold it in place. Zone 0 – the interior of the bath or shower which can hold water. No appliances should be installed here period! In this example here we are using an existing lighting circuit so a 1mm twin and earth cable is run out from the top of the ceiling rose, down through the ceiling and down a chase that was cut into the wall. In both cases, the cables are run down through the ceiling and down a chase cut into the wall to run to both locations Once a suitable supply has been found the next task is to isolate the supply to the circuit you are using! If in any doubt, the power to the entire house is turned off.

If no supplies are this conveniently placed then it may be that you have to take up some floorboards in an above room and run your supply from here.However if you are installing in an upstairs then you may be able to locate a suitable supply in the loft. This is often the easiest route as everything should be much more accessible. The front of a shaver supply unit is marked with the rated voltage(s) and with the symbol shown left. A degree of protection of at least IPX1 is provided by a shaver supply unit.

In the UK there are very strict rules on who can and cannot do certain electrical jobs. This is mainly due to the fact that, as we all know, electricity is extremely dangerous and when working on or around it, it is essential that you know what you are doing.If either of the above are ignored, if any issues occur and you cannot produce a certificate for the works then there is a good chance that your home insurance will be invalid, so it certainly isn’t worth the risk. Once in place the cable was then tested to ensure there were no breaks etc. This is a necessary step as once the cable is filled over it’s a nightmare to have to dig it all out if it’s damaged. As we have mentioned above, when running down a wall to a power supply unit such as this the cable will need to run vertically down in a straight line to comply with regulations.

Ideally look for a model with double wound isolating transformer, integral overload protection and shutters on the plug inlets to prevent any accidental splashing. A shaver supply unit complying with BS EN 61558-2-5 may be installed in zone 2 of a location containing a bath or shower (Regulation 701.512.3 refers). The cable was then secured in place using UPVC capping to not only hold it but also protect it from any damage that might from any potential future work.

Different Types of Shaver Socket

Zone 1 – the area directly above zone 0, limited vertically to 2.25m above the bottom of the bath or shower, also 1.2m horizontally from the centre of a shower outlet to the height of the outlet, or 2.25m whichever is the higher A thermal cut-out is provided in a shaver supply unit to limit the temperature of the transformer under conditions of short-circuit or overload. The cut-out may be of either the self-resetting type or the manually resetting type. Zone 2 – the area beyond zones 0 and 1, 0.6m horizontally and up to 2.25m vertically. Zone 2 also includes any recessed window with a sill next to the bath and also around the wash basin Once this is done, a minor works certificate is then issued to prove the installation has been carried out correctly.